Instant Alcohol Testing Kits Alcohol Saliva Rapid Screening Test
Specifications:
No need additional equipment
Room temperature storage
Detailed Product Description:
Saliva Alcohol Test Strip
1.formats:strip
2.specimens:saliva
3.read in 2min
4.accuracy:above 99.6%
One Step Saliva Alcohol Test Strip
One Step Alcohol Saliva Test Strip is intended for use as a rapid method to detect the presence of alcohol in saliva for blood alcohol concentration (BAC) greater than 0.02%. It has been published that the concentration of alcohol in saliva is almost equal to that in blood.
Descriptions:
Product name | Alcohol Saliva Test Strip Kits |
Formats | strip |
Specification | 2.5mm 3.0mm |
Sensivity | 0.02g/dL |
Accuracy | 99% |
Specimens | saliva |
Use | selt-test, professional-test, home-test |
Read Time | 30seconds-2mins |
Storage | Room temperature |
Shelf Time | 24-36months from the date of manufacture |
Shipping | By Sea or By Air |
Package | one strip in one foil pouch |
Deliever Time | 5-30days depend on your order quantity and requirements |
Intended Use:
Rapid Saliva Alcohol Test Strip is intended for use as a rapid method to detect the presence of alcohol in saliva for blood alcohol concentration (BAC) greater than 0.02%. It has been published that the concentration of alcohol in saliva is almost equal to that in blood.
The rapid test is intended for the semi-quantization of ethyl alcohol in human saliva. To confirm the concentration of positive specimens, an alternate, non-enzymatic technology such as headspace gas chromatography should be used.
1. Remove a strip from the foil pouch by tearing at the notch and place it on a level surface.
2. Saturate the reactive pad by dipping the reaction pad into the saliva specimen collected in a sputum cup, or by applying saliva directly to the reaction pad. After 10 seconds, shake off the excess saliva.
3. Immediately start timer and at 2 minutes, compare the reactive pad with the provided colored chart below.
Positive(+):
A distinct color developed all over the pad. The positive result indicates that the BAC is 0.02% or higher. The alcohol concentration are related to the colored chart above.
Negative (-):
Almost no color change by comparing with the background. The negative result indicates that the BAC is less than 0.02%.
Invalid:
The test should be considered invalid If only the edge of the reactive pad turned color that might be ascribed to insufficient sampling. The subject should be re-tested.
We have more categories for you. lf you can't find the products you want above,just fill in the form and tell us whatproducts you want to import from China.